LEMON Manuals: Even more car manuals for everyone
Home >> Porsche >> 2011 >> 911 Speedster >> Repair and Diagnosis >> External Pages >> Different car >> Section 9 (Lights, Lamps, Switches Interior, Theft Protection Diagnosis - 911 CARRERA (996)) >> Control unit function >> Function display and audible checkback

Function display and audible checkback

WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2005 Porsche 911, 2004 Porsche 911, 2003 Porsche 911, 2002 Porsche 911, and 2001 Porsche 911. However, it is still accessible from the selected car via links, so may be relevant.

The operating state of the central locking system is fed back via the output Door locked and by corresponding activation of the interior light (signals 1 to 3). The operating state of the alarm system is also indicated during the inactive period by the alarm readiness display (display types 1 to 6). It is indicated exclusively by the alarm readiness display after the inactive period has expired. Displayed system faults are always current faults. Previous system faults entered in the status memory have no effect on the function display.

FUNCTION DISPLAY TYPE 1 (NORMAL FLASHING)

Display type 1 (normal flashing)
Requirement: Alarm system primed
No alarm output or no active alarm input after re-locking if no alarm input is active.
Duration: Until deactivation, then display type 6.
LED flashes with a frequency of 0.5 Hz
On time 100 ms
Out time 1,900 ms
FUNCTION DISPLAY TYPE 2 (DOUBLE FLASHING)

Display type 2 (double flashing)
Requirement: After alarm output or active alarm input following activation or re-locking.
Duration: Until deactivation, then display type 6.
LED flashes with a frequency of 0.5 Hz
On time 1, 2 100 ms
Out time 1 200 ms
Out time 2 1,700 ms
FUNCTION DISPLAY TYPE 3 (RAPID FLASHING)

Display type 3 (rapid flashing)
Requirement: Alarm system primed
No active alarm inputs.
Duration: Inactive period, then display type 1.
LED flashes with a frequency of 2 Hz
On time 100 ms
Out time 400 ms
FUNCTION DISPLAY TYPE 4 (RAPID FLASHING)

Display type 4 (rapid flashing)
Requirement: Reception of an adapted hand-held transmitter.
Duration: Push of the button
LED flashes with a frequency of 10 Hz
On time 50 ms
Out time 50 ms
FUNCTION DISPLAY TYPE 5 (ON)

Display type 5 (on)
Requirement: After central locking system emergency locking or after locking command is given twice via hand-held transmitter or door lock.
Duration: For inactive period following central locking system emergency locking, then display type 2 for inactive period following locking command given twice, then display type 1.
LED is continuously on.
FUNCTION DISPLAY TYPE 6 (OFF)

Display type 6 (off)
LED is not switched on.

In addition, the checkback of faults and of the standard status is performed with signal 3 at the interior light output. An audible checkback via the alarm horn output also takes place at the alarm system control module, together with a visual checkback via the outputs for the direction indicator lights.

INTERIOR LIGHT OUTPUT SIGNAL 1

Signal 1:
The outputs are triggered once.
On time 50 ms
INTERIOR LIGHT OUTPUT SIGNAL 2

Signal 2:
The outputs are triggered twice.
On time 1, 2 50 ms
Out time 200 ms
INTERIOR LIGHT OUTPUT SIGNAL 3

Signal 3:
The outputs are triggered once.
On time 2,500 ms

These functions can be switched on and off with the Porsche System Tester II 9588, depending on the country variants. The times are freely programmable.

Assignment of the display type of the alarm readiness light to the operating state.

DISPLAY TYPE ASSIGNMENT OF ALARM READINESS LIGHT TO OPERATING STATE

Operating conditions: Display type: Operating state:
During inactive period
Self-test OK, central locking system locked and secured, all inputs in normal position, not locked 3 times. Rapid flashing (3) Not primed.
Self-test OK, central locking system locked, all inputs in normal position, not locked 3 times. On (5) Not primed.
Self-test not OK. Off (6) Not primed.
Self-test OK, central locking system must not be locked, not locked 3 times. Off (6) Not primed.
Self-test OK, central locking system locked, active inputs. Off (6) Not primed.
Self-test OK, locking/priming by locking 3 times. On (5) Not primed.
Inactive period expired.
All inputs inactive, central locking system locked and secured, not locked 3 times, no alarm. Normal flashing (1) Primed.
All inputs inactive, central locking system locked, no alarm, not locked 3 times. Normal flashing (1) Primed.
Inputs active. Double flashing. Primed for all inactive inputs.
During or after alarm output. Double flashing. Primed.
Priming/locking command by 3 x rapid locking of the system. Double flashing. (2) Primed.
Self-test not OK. Off (6) Not primed.

If a control command is issued via the hand-held transmitter, this is confirmed with display type 4 for the duration of the operation. This display has priority.