Removing Coolant Pump
Information
Specifications for wrench sizes (a/f specifications) for screw heads are described as follows:
- Torx screws: (E..) for external Torx, (T..) for internal Torx.
- Hexagon-head bolts (internal and external hexagon): Wrench size (a/f)
- Unscrew six external Torx screws -2 and 3-
on the coolant pump.
- Coolant pump
- 5 x external Torx screw (E10), M6 x 20
- 1 x external Torx screw (E12, M8 x 25)
- Remove coolant pump.
- 2.1. Collect emerging coolant in a clean container.
- 2.2. The pump seal can be reused if there are no visible signs of damage.
- Check coolant pump pulley for damage and replace the coolant pump if necessary.
- Carefully clean the sealing faces.