Checking Battery Charging Condition With Battery Tester
- Check the battery charging condition according to the operating instructions for the relevant rapid-start battery charger.
EVALUATING TEST RESULTS AND FURTHER PROCEDURES
| Open-circuit voltage in volts | Battery charging condition in % | Evaluation and procedure |
|---|---|---|
| 12.7 - 12.5 | 100 - 80 | Battery charging condition OK |
| 12.5 - 12.2 | 80 - 50 | Battery charging condition reduced, recharge battery and observe an inactive period for two hours after charging. → 270601 CHECKING BATTERY |
| 12.2 - 11.6 | 50 - 10 | Battery flat; recharge battery and observe an inactive period for two hours after charging. → 270601 CHECKING BATTERY |
| below 11.6 | below 10 | Battery totally discharged; replace battery. → 270619 REMOVING AND INSTALLING BATTERY |