Removing Deformation Element
WARNING:
Damaged deformation elements
- Reduced accident protection
→ The deformation elements must not be repaired.
→ Replace the deformation elements in the event of visible damage or pressure marks.
- Release electric line slightly upwards.
- Drill out blind rivets -1- with a 4 mm drill and remove the deformation element -A- .