Fitting Mounting Points For The Hardtop Locking Lever On The Plate
Fit. mounting -A3- for the hardtop locking lever on the plate -D- .
- -A3- = Base
- -A7- = Hexagon-head bolt 6 x 20 with disc
- -B- = Support cheek
- -D- = Base plate
- Work procedure:
- 1.1. Fit mounting points -A3- both with hexagon-head bolts -A7- according to the dimensions specified on the plate -D- .