Filling And Bleeding The Dfi Fuel High-Pressure System
- Start the engine and allow to run at idle speed. This can result in a rough-running engine and the Check Engine warning light in the instrument cluster can be activated.
- Turn off the engine and switch off ignition.
- Switch on ignition.
- Read out and erase the fault memory of the DME control unit using the PIWIS Tester.
- Switch off ignition.
- Switch the ignition on and start the engine.
- The bleeding process is complete when the engine runs smoothly, the Check Engine warning light is no longer activated and no additional faults are entered in the fault memory.
- Perform a test drive.