Preparing Adhesive Flanges: Hardening

The body structural adhesive used hardens at room temperature. Hardening can be accelerated by heat (e.g. with an infrared radiator in a painting booth). Do not load bonded parts until hardening is complete.

  Teromix 6700 adhesive set Terokal 5045 adhesive set
Initial strength at (23 °C) Approx. 2 h Approx. 6 h
Hardening time at room temperature (23 °C) Approx. 6 h Approx. 36 h
Hardening time at 80 °C Approx. 10 min Approx. 45 min
Max. hardening temperature Approx. 140 °C (1) Approx. 180 °C (2)
(1) After this time assembly work is permitted 
(2) Quick (max. 1 h)