LEMON Manuals: Even more car manuals for everyone
Home >> Porsche >> 2004 >> 911 GT2 >> Repair and Diagnosis >> Brakes >> Anti-Lock Brakes >> Anti-Lock Brake System (Abs/PSM 5.7) - Diagnosis - 911 Turbo (996) >> Fault code 4460 >> Diagnosis/troubleshooting

Fault code 4460: Diagnosis/troubleshooting

DIAGNOSIS/TROUBLESHOOTING CHART - FAULT CODE 4460

Work instruction Display OK If not OK
1 Visual inspection
  • Check the pressure sensor plug for damage and corrosion
Step 2 Repair pressure sensor plug
2 Check supply voltage of the pressure sensor for short circuit to ground/open circuit
  • Switch off ignition
  • Pull off pressure sensor plug
  • Switch on ignition
  • Measure voltage between pin 3 of pressure sensor plug and ground
approx. 5 V
Step 3
  • Display 0 V:

    Short circuit to ground/open circuit in circuit between PSM control module plug pin 42 and pressure sensor plug pin 3

  • Display > 11 V

    Short circuit to voltage between PSM control module plug pin 42 and pin 3 of the booster pump pressure sensor plug, or PSM contol module faulty


-> End
3 Check ground of pressure sensor for open circuit
  • Measure voltage between pin 3 of the booster pump pressure sensor plug and pin 1 of the booster pump pressure sensor plug
approx. 5 V
Step 4
Open circuit in circuit between PSM control module plug pin 25 and pin 1 of the booster pump pressure sensor plug, or PSM contol module faulty
-> End
4 Check signal lead of the pressure sensor for short circuit to voltage
  • Measure voltage between pin 2 of the booster pump pressure sensor plug and ground
< 0.3 V
Step 5
Short circuit to voltage between pin 2 of booster pump pressure sensor plug and PSM control module plug pin 26 -> End
5 Check signal lead of the pressure sensor for short circuit to ground
  • Switch off ignition
  • Measure resistance between pin 2 of the booster pump pressure sensor plug and ground
< 5
Step 6
Short circuit to ground between pin 2 of booster pump pressure sensor plug and PSM control module plug pin 26
-> End
6 Check signal lead of the pressure sensor for open circuit
  • Measure resistance between pin 2 of the booster pump pressure sensor plug and PSM control module plug pin 26
< 5
Step 7
Open circuit between pin 2 of the booster pump pressure sensor plug and PSM control module plug pin 26
-> End
7 Replace hydraulic unit -> End