Fault code 4276: Diagnosis/troubleshooting
DIAGNOSIS/TROUBLESHOOTING CHART - FAULT CODE 4276
| Work instruction | Display OK | If not OK | ||
|---|---|---|---|---|
| 1 | Check supply voltage of the valve relay |
|
> 11 V Step 2 | Check following components:
-> End |
| 2 | Replace hydraulic unit | -> End | ||