LEMON Manuals: Even more car manuals for everyone
Home >> Porsche >> 2004 >> 911 GT2 >> Repair and Diagnosis >> Body & Frame >> Door Locks >> Lights, Lamps, Switches Interior, Theft Protection Diagnosis - 911 Turbo (996) >> Fault code 45 >> Diagnosis/troubleshooting

Fault code 45: Diagnosis/troubleshooting

DIAGNOSIS/TROUBLESHOOTING (FAULT CODE 45)

Work instruction Display OK If not OK
1 Check wiring from the alarm system control module to the door locks for short circuit to B+
  • Pull plug off the two door locks
  • Pull plugs A and B off the alarm system control module
  • Switch on ignition
  • Measure voltage between plug B on alarm system control module pin 3 and ground
  • Measure voltage between plug B on alarm system control module pin 9 and ground
0 V
Step 2
Repair wiring harness
-> End
2 Check servomotors for left door lock
  • Switch off ignition
  • Reconnect plug to left door lock
  • Disconnect plug connection X11
  • Measure resistance on plug connection X 11 (sleeve side) between pins 11 and 17
  • On vehicles with "safe position": Measure resistance on plug connection X 11 (sleeve side) between pins 11 and 24
5 -- 7 at 20°C
Step 3
Replace left door lock
-> End
3 Check servomotors for right door lock
  • Reconnect plug to right door lock
  • Disconnect plug connection X12
  • Measure resistance on plug connection X 12 (sleeve side) between pins 11 and 17
  • On vehicles with "safe position": Measure resistance on plug connection X 12 (sleeve side) between pins 11 and 24
5 -- 7 at 20 °C
Step 4
Replace right door lock
-> End
4
  • Replace alarm system control module
-> End