Fault overview
FAULT CODE OVERVIEW - SEAT MEMORY
| Fault code | Fault text | Fault effect |
|---|---|---|
| 1 | Control module faulty (main relay does not drop out) | No adjustment |
| 2 | Control module faulty (main relay does not pick up) | No adjustment |
| 3 | Control module faulty (A/D converter faulty) | No adjustment |
| 4 | EEPROM fault (checksum) | Default values |
| 5 | EEPROM fault, Required position 1 (checksum) | No automatic adjustment possible |
| 6 | EEPROM fault, Required position 2 (checksum) | No automatic adjustment possible |
| 7 | EEPROM fault, Required position 3 (checksum) | No automatic adjustment possible |
| 8 | Hall-effect sensor for fore-and-aft adjustment - open circuit | No automatic adjustment possible, manual only 500 ms |
| 9 | Hall-effect sensor for fore-and-aft adjustment - short circuit | No automatic adjustment possible, manual only 500 ms |
| 10 | Hall-effect sensor for backrest adjustment - open circuit | No automatic adjustment possible, manual only 500 ms |
| 11 | Hall-effect sensor for backrest adjustment - short circuit | No automatic adjustment possible, manual only 500 ms |
| 12 | Hall-effect sensor for front height adjustment - open circuit | No automatic adjustment possible, manual only 500 ms |
| 13 | Hall-effect sensor for front height adjustment - short circuit | No automatic adjustment possible, manual only 500 ms |
| 14 | Hall-effect sensor for rear height adjustment - open circuit | No automatic adjustment possible, manual only 500 ms |
| 15 | Hall-effect sensor for rear height adjustment - short circuit | No automatic adjustment possible, manual only 500 ms |
| 18 | Lumbar pressure sensor - open circuit | No automatic lumbar adjustment possible |
| 19 | Lumbar pressure sensor - short circuit | No automatic lumbar adjustment possible |
| 20 | Pot. mirror right horizontal - open circuit | No automatic adjustment possible |
| 21 | Pot. mirror right horizontal - short circuit | No automatic adjustment possible |
| 22 | Pot. mirror right vertical - open circuit | No automatic adjustment possible |
| 23 | Pot. mirror right vertical - short circuit | No automatic adjustment possible |
| 24 | Pot. mirror left horizontal - open circuit | No automatic adjustment possible |
| 25 | Pot. mirror left horizontal - short circuit | No automatic adjustment possible |
| 26 | Pot. mirror left vertical - open circuit | No automatic adjustment possible |
| 27 | Pot. mirror left vertical - short circuit | No automatic adjustment possible |
| 32 | Button M, 1, 2, 3 or operating buttons actuated for longer than 60 seconds | Switch is ignored; all further adjustments are jerky |