8007 Pcm2 - MMI: Diagnosis/troubleshooting
DIAGNOSIS/TROUBLESHOOTING (8007 PCM2 - MMI)
| Work instruction | Display OK | If not OK | ||
|---|---|---|---|---|
| 1 | Read out PCM2 fault memory |
|
The fault is remedied -> End |
Fault code is still displayed Step 2 |
| 2 | Check diagnosis distribution line for open circuit | Check diagnosis distribution line between the listed faulty components for an open circuit
|
< 0.5 STEP 3 |
Remove open circuit in diagnosis distribution line -> End |
| 3 | Check diagnosis distribution line for short circuit to ground | Check diagnosis distribution line between the listed faulty components for short circuit to ground
|
Step 4 | Remove short circuit to ground in diagnosis distribution line -> End |
| 4 | Check diagnosis distribution line for short circuit to B+ | Check diagnosis distribution line between the listed faulty components for short circuit to B+
|
0 Volt STEP 5 |
Remove short circuit to B+ in diagnosis distribution line -> End |
| 5 | Replace PCM2 | -> End | ||