Pot. 2, convertible-top compartment lid
WARNING: This page is about a different variant/trim than selected.
The values between pot. 2, calibration value 2, and pot. 1, calibration value 4, are calculated as percentage by the convertible-top control module.
If the actual values (measured values) of calibration values 1 and 4 differ, the CTCL potentiometer must be adjusted. Refer to REMOVING AND INSTALLING CONVERTIBLE-TOP COMPARMENT LID DRIVE .
- Pot. 2 calibration value 1 Tester display must be greater than > 1.0 volts
- Pot. 2 calibration value 2
- Pot. 2 calibration value 3
- Pot. 2 calibration value 4 Tester display must be less than < 3.9 volts < 3.9 volts