Possible causes, elimination, notes
WARNING: This page is about a different variant/trim than selected.
This fault is only stored in the memory if the voltage at the input of the convertible-top potentiometer exceeds or falls below the operating range.
- Switch ignition off and remove ignition key. With test adapter 9619, 9636 and pin template 9636, measure the resistance of the convertible-top potentiometer at row 1, pins 12, 21 and 24 with the ohmmeter. If the display "INFINITY" ohm appears, the convertible-top potentiometer must be replaced.
Refer to REMOVING AND INSTALLING POTENTIOMETER FOR CONVERTIBLE-TOP INTERROGATION .
- Switch on the ignition and measure at row 1, pins 12 and 21, with the voltmeter; nominal value (display) 0.4 - 4.4 volts.
If there is no voltage display, replace the control module.
- Calibrate the convertible top