Switch short circuit to ground: Diagnosis/troubleshooting
WARNING: This page is about a different variant/trim than selected.
DIAGNOSIS/TROUBLESHOOTING FOR FAULT CODE 2
| Work instruction | Display OK | If not OK | ||
|---|---|---|---|---|
| 1 | Check input signals for convertible top switch |
|
Convertible-top button not actuated is displayed (both input signals indicate open) Step 2 |
Step 4
Step 6 |
| 2 | Check input signal open on convertible top control unit using alarm system control unit |
|
< 0.3V
approx. 9 V to 10 V Step 3 |
Step 9 |
| 3 | Check input signal close on convertible top control unit using alarm system control unit |
|
< 0.3V
>11 V Step 13 |
Step 9 |
| 4 | Check convertible top switch input signal open on convertible top control unit |
|
< 5
Step 13 |
Step 5 |
| 5 | Check wire between convertible top switch open and convertible top control unit for short circuit to ground |
|
< 5 Step 8 |
Repair wiring harness ->End |
| 6 | Check convertible top switch input signal close on convertible top control unit |
|
< 5
Step 13 |
Step 7 |
| 7 | Check wire between convertible top switch close and convertible top control unit for short circuit to ground |
|
< 5 Step 8 |
Repair wiring harness ->End |
| 8 | Check wires between convertible top switch and convertible top control unit for short circuit |
|
Step 11 | Repair wiring harness ->End |
| 9 | Check wires between alarm for motor and convertible top control unit for short circuit to ground |
|
Step 10 | Repair wiring harness ->End |
| 10 | Check wires between alarm system control unit and convertible top control unit for short circuit |
|
Step 12 | Repair wiring harness ->End |
| 11 |
|
->End | ||
| 12 |
|
See alarm system diagnosis | ||
| 13 |
|
->End | ||