Fault code 39: Diagnosis/troubleshooting
DIAGNOSIS/TROUBLESHOOTING (FAULT CODE 39)
| Work instruction | Display OK | If not OK | ||
|---|---|---|---|---|
| 1 | Check power supply of the signal converter |
|
> 11 V Step 2 |
Repair wiring harness |
| 2 | Check wiring from signal converter to alarm system control module for short circuit to ground |
|
Step 3 | Repair wiring harness -> End |
| 3 | Check wiring from signal converter to alarm system control module for short circuit to B+ |
|
0 V Step 4 |
Repair wiring harness -> End |
| 4 | Check wiring from signal converter to alarm system control module for open circuit |
|
< 5 Step 5 |
Repair wiring harness -> End |
| 5 |
|
-> End | ||