Fault code 10: Diagnosis/troubleshooting
DIAGNOSIS/TROUBLESHOOTING (FAULT CODE 10)
| Work instruction | Display OK | If not OK | ||
|---|---|---|---|---|
| 1 | Visual inspection |
|
Step 2 | Repair plug B or wiring harness -> End |
| 2 | Check power supply (terminal 30) |
|
> 11 V Step 7 |
Step 3 |
| 3 | Check wiring from the "mini relay" to the alarm system control module for open circuit |
|
< 5 Step 4 |
Repair wiring harness -> End |
| 4 | Check wiring from the current distributor (F5) to the mini-relay carrier |
|
> 11 V Step 5 |
Repair wiring harness or check fuse in current distributor -> End |
| 5 | Check wire from ground point 3 to the mini-relay carrier |
|
< 5 Step 6 |
Repair wiring harness or check ground point 3 for corrosion -> End |
| 6 |
|
-> End | ||
| 7 |
|
-> End | ||