Reading out and transferring remote control: Procedure

  1. Connect PST2 to the data link connector, and switch on the ignition.
  2. Switch on the PST 2, select vehicle type 911 (996) and start the automatic control module search with the double arrow key ">>".
  3. After a brief search, the PST2 reports: "Fault memory reading completed".
  4. Select alarm system control module and press the double arrow key ">>".
  5. Select "Learning function" in the menu and press the double arrow key ">>".
  6. Select menu item Read out remote control and press the double arrow key ">>".
  7. "Input key learning code" appears on the screen. Input the key learning code with the arrow keys [ ] and [ ] and press the double arrow key ">>".
  8. "Please confirm input" appears on the screen. Check the input key learning code and press the "F8" key.
  9. "Remote controls were read out" appears on the screen. Press the double arrow key "<<" twice in order to change to the control module overview. Switch the ignition off, remove the old control module, install the new control module and switch the ignition on again.
  10. Press the double arrow key "<<" to set up communication with the new control module.
  11. Select the menu item "Learning functions" with the arrow key [ ] and press the double arrow key ">>".
  12. The menu item "Immobilizer" is already selected. Press the double arrow key ">>".
    CAUTION: The immobilizer code can be input only once.
    An incorrect input will render the control module useless!
    • Input and check immobilizer code carefully.
  13. "Input immobilizer code" appears on the screen. Input the immobilizer code with the arrow keys [ ] and [ ] and press the double arrow key ">>".
  14. "Please confirm input" appears on the screen. Check the input immobilizer code and press the "F7" key.
  15. Select the menu item "Transfer remote control" with the arrow key [ ] and press the double arrow key ">>".
  16. "Input key learning code" appears on the screen. Input the key learning code with the arrow keys [ ] and [ ] and press the double arrow key ">>".
  17. "Please confirm input" appears on the screen. Check the input key learning code and press the "F7" key.
  18. "Remote controls were transferred" appears on the screen.
  19. Select the menu item "Transponder key" with the arrow key [ ] and press the double arrow key ">>".
  20. "Input key learning code" appears on the screen. Input the key learning code with the arrow keys [ ] and [ ] and press the double arrow key ">>".
  21. "Please confirm input" appears on the screen. Check the input key learning code and press the "F7" key.
    NOTE:
    • As the transponder coils must be taught individually, make sure that the allocation of the locations is the same as described under "Transponder code" on the IPAS printout (see step 22).
  22. Four unoccupied positions are displayed on the screen. Position 1 is marked in black. Furthermore, the current transponder code is displayed under "Current key". This code must be stored in the same location as specified in the IPAS printout. Select position and press the "F8" key. The position is occupied with the corresponding transponder code.
  23. Withdraw the key and repeat steps 19 to 22 for the remaining keys.

All remote controls have now been transferred from the old control module to the new control module, and the transponders adapted to the new control module.