8009 Pcm2 - MMI: Diagnosis/troubleshooting

DIAGNOSIS/TROUBLESHOOTING (8008 PCM2 - MMI)

Work instruction Display OK If not OK
1 MOST component check automatic run
  • In the Control units menu, select PCM2
  • Click MOST components check in the function selection and start it with the ">>" key
  • Follow the instructions of the tester
The following text is displayed:
Test successfully completed. No faults found.
-> End
Tester displays an optical fault:
Under Faulty device, the tester displays the relevant
MOST control unit from which no appropriate signal is detected.
Step 2
Tester displays an electrical fault:
Step 7
2 Open circuit in MOST, optical
  • Replace the optical waveguide to the MOST control unit displayed with the optical wavelength test line 9712
  • Erase fault memory 8009.
  • Select MOST components check and start it again with the ">>" key
  • Follow the instructions of the tester.
The following text is displayed:
Test successfully completed. No faults found
Step 3
Step 4
3 Replace the optical waveguide -> End
4 Open circuit in MOST, optical If an MMI or GW fault is displayed under step 2:
  • Connect optical output with the optical input of the MOST control unit which is installed before the PCM2 with the optical waveguide test line 9712.

If only 1 external MOST control unit is present and fault memory entry under step 1 is not MMI or GW:
Otherwise
  • Connect the optical waveguide test line 9712 with the next Most control unit displayed under step 1 (do not change the input of the optical waveguide test line).

After installing Optical waveguide test line 9712 :
  • Erase fault memory 8009.
  • Select MOST components check and start it again with the ">>" key.
  • Follow the instructions of the tester.
If an MMI or GW fault is displayed under step 2:
Fault memory entry 8009 = MMI or GW
Step 5
If only 1 external MOST control unit is present and fault memory entry under step 1 is not MMI or GW:
Fault memory entry 8009 = MMI or GW
Step 6
Otherwise:
The following text is displayed:
Test successfully completed. No faults found.
Step 5
->End
If an MMI or GW fault is displayed under step 1:
Fault memory entry 8009 is not MMI or GW
Step 6
If only 1 external MOST control unit is present and fault memory entry under step 1 is not MMI or GW:
Fault memory entry 8009 is not MMI or GW
Step 5
Otherwise:
Step 6
5 Replace the control unit displayed under step 1. -> End
6 Replace the control unit before the one displayed under step 1. -> End
7 Check the power supply of the displayed control unit. Step 8 Repair
-> End
8 Check wiring of the ring break diagnosis line. Step 9 Repair
-> End
9 Replace displayed control unit -> End -