8009 CDR23: Diagnosis/troubleshooting

DIAGNOSIS/TROUBLESHOOTING (8009 CDR23)

Work instruction Display OK If not OK
1 MOST component check runs automatically
  • Connect the Porsche System Tester II 9588 to the diagnostic socket, start it and switch on the ignition.
  • Select 911 Turbo (996) in the Vehicle type menu and confirm with the ">>" key.
  • Select PCM in the Control units menu and confirm with the ">>" key.
  • Select MOST component check in the PCM2 function selection and confirm with the ">>" key.
  • Follow the instructions of the tester
The following text is displayed:
Test successfully completed. No faults found.
-> End
Tester displays an optical fault:
Under faulty device, the tester displays the relevant MOST control unit from which no appropriate signal is detected.
Step 2
Tester displays an Electrical fault.
Step 7
2 Open circuit in MOST, optical
  • Replace the optical waveguide for the MOST control unit with the optical wavelength test line 9712
  • Erase fault memory 8009
  • Select MOST components check and start it again with the ">>" key
  • Follow the instructions of the tester.
The following text is displayed:
Test successfully completed. No faults found
Step 3
Step 4
3 Replace the optical waveguide -> End
4 Open circuit in MOST, optical If an MMI or GW fault is displayed under step 1:
  • Connect optical output with the optical input of the MOST control unit which is installed before the PCM2 with the optical waveguide test line 9712.

If only 1 external MOST control unit is present and fault memory entry under step 1 is not MMI or GW:
Otherwise
  • Connect the optical waveguide test line 9712 with the next Most control unit displayed under step 1 (do not change the input of the optical waveguide test line).

After installing Optical waveguide test line 9712 :
  • Clear fault memory 8009.
  • Select MOST components check and start it again with the ">>" key.
  • Follow the instructions of the tester.
If an MMI or GW fault is displayed under step 1:
fault memory entry 8009 = MMI or GW
Step 5
If only 1 external MOST control unit is present and fault memory entry under step 1 is not MMI or GW:
fault memory entry 8009 = MMI or GW
Step 6
Otherwise:
The following text is displayed:
Test successfully completed. No faults found.
Step 5
-> End
If an MMI or GW fault is displayed under step 1:
fault memory entry 8009 is not MMI or GW
Step 6
If only 1 external MOST control unit is present and fault memory entry under step 1 is not MMI or GW:
fault memory entry 8009 is not MMI or GW
Step 5
Otherwise:
Step 6
5 Replace the control unit displayed under step 1. -> End
6 Replace the control unit before the one displayed under step 1. -> End
7 Check the power supply of the displayed control unit. Step 8 Repair
-> End
8 Check wiring of the ring break diagnosis line. Step 9 Repair
-> End
9 Replace displayed control unit -> End