Possible causes, elimination, notes
Diagnosis conditions
No control module fault stored.
No fault with supply voltage (5 volts).
Signal implausible
- Check temperature mixing valve for smooth operation.
- Unplug connectors A, B, C and D from the heating/air-conditioning control.
- Unplug connector from the temperature mixing valve drive motor.
- Connect ohmmeter to connector C 8 and drive motor connector pin 1.
Display: < 5 ohm
Connect ohmmeter to connector B 8 and drive motor connector pin 2.
Display: < 5 ohm
Connect ohmmeter to connector A 12 and drive motor connector pin 3.
Display: < 5 ohm;
Connect ohmmeter to connector D 10 and drive motor connector pin 4.
Display: < 5 ohm
Connect ohmmeter to connector D 2 and drive motor connector pin 5.
Display: < 5 ohm
- Check wire from connector C 8 to drive motor pin 1 for short to B+ and short to ground.
- Check wire from connector B 8 to drive motor pin 2 for short to B+ and short to ground.
- Check wire from connector A 12 to drive motor pin 3 for short to B+.
- Check wire from connector D 10 to drive motor pin 4 for short to B+ and short to ground.
- Check wire from connector D 2 to drive motor pin 5 for short to B+ and short to ground.