Possible causes, elimination, notes
Diagnosis conditions
No control module fault stored.
No fault with supply voltage (5 volts).
Outside temperature higher than - 30 °C.
Open circuit
- Unplug connectors A and B from the heating/air-conditioning control.
- Connect ohmmeter to connectors A 12 and B 5.
Display: approx. 2.8 kohm at 23 °C
- Unplug connector from blower outlet sensor.
- Connect ohmmeter to connector A 12 and blower outlet sensor connector pin 2.
Display: < 5 ohm
- Connect ohmmeter to connector B 5 and blower outlet sensor connector pin 1.
Display: < 5 ohm
- Connect voltmeter to connector B 5 and ground. Switch on ignition.
Display: 0 volts
If approx. 5 volts are displayed, check wiring harness for pinching and chafing damage.
Short to ground
- Unplug connector B from the heating/air-conditioning control.
- Connect ohmmeter to connector B 5 and ground.
Display: "INFINITY" ohm
If 0 - 5 ohm is displayed, check wiring harness for pinching and chafing damage.