Possible causes, elimination, notes
Diagnosis conditions
No control module fault stored.
No fault with supply voltage (5 volts).
Outside temperature higher than - 40 °C.
Open circuit
- Unplug connector A from the heating/air-conditioning control.
- Connect ohmmeter to connectors A 10 and A 12.
Display: approx. 3 kohm at 23 °C
NOTE: The wires to the interior temperature sensor are routed via two additional plug connections on the heating/air-conditioning control. - Unplug connector from the interior temperature sensor.
- Connect ohmmeter to connector A 10 and interior sensor connector pin 5.
Display: < 5 ohm
- Connect ohmmeter to connector A 12 and interior sensor connector pin 4.
Display: < 5 ohm
- Connect voltmeter to connector A 10 and ground. Switch on ignition.
Display: 0 volts
If approx. 5 volts are displayed, check wiring harness for pinching and chafing damage.
Short to ground
- Unplug connector A from the heating/air-conditioning control.
- Connect ohmmeter to connector A 7 and ground.
Display: "INFINITY" ohm
If 0 - 5 ohm is displayed, check wiring harness for pinching and chafing damage.