Possible causes, elimination, notes
Diagnosis conditions
No control module fault stored.
No fault with supply voltage (5 volts).
Open circuit
- Unplug connector A from the heating/air-conditioning control.
- Connect ohmmeter to connectors A 7 and A 12.
Display: approx. 1.2 kohm at 23 °C
- Unplug connector from the outside temperature sensor.
- Connect ohmmeter to connector A 7 and pin 1 (connector of outside temperature sensor).
Display: 0 - 5 ohm
- Connect ohmmeter to connector A 12 and pin 2 (connector of outside temperature sensor).
Display: 0 - 5 ohm
- Connect voltmeter to connector A 7 and ground. Switch on ignition.
Display: 0 volts
If approx. 5 volts are displayed, check wiring harness for pinching and chafing damage.
Short to ground
- Unplug connector A from the heating/air-conditioning control.
- Connect ohmmeter to connector A 7 and ground.
Display: "INFINITY" ohm
If 0 - 5 ohmis displayed, check wiring harness for pinching and chafing damage.