Possible causes, elimination, notes
Diagnosis conditions
No control module fault stored.
Supply voltage OK.
Nominal blower voltage > 3 volts.
Nominal blower voltage stabilized.
Voltage too low
- Check the heating activation relay.
Battery positive voltage must be present at terminal 87 when the ignition is switched on.
- Unplug connector C from the heating/air-conditioning control.
- Connect voltmeter to C 14 (positive) and ground. Switch on ignition.
Display: Battery voltage
- Push connector C on the heating/air-conditioning control.
- Connect voltmeter to C 14 (positive) and C 11 (negative).
Maximum blower speed
Display: approx. 12 V
Minimum blower speed
Display: approx. 0 V
- Connect voltmeter to C 14 (positive) and C 16 (negative).
Maximum blower speed
Display: approx. 5 V
Minimum blower speed
Display: approx. 9 V
- Check driver.
Connect voltmeter to positive and pin 3 on driver connector.
Display: Battery voltage
Connect voltmeter to positive and pin 1 on driver connector.
Maximum blower speed
Display: approx. 5 V
Minimum blower speed
Display: approx. 9 V
Connect voltmeter to positive and pin 2 on the driver connector.
Maximum blower speed
Display: approx. 12 V
Minimum blower speed
Display: approx. 0 V
- Check wiring from heating/air-conditioning control to driver for continuity.
- Check blower motor.
Voltage too high
- Unplug connector C from the heating/air-conditioning control.
- Unplug connector from the driver.
- Connect ohmmeter to C 16 and ground.
Display: "INFINITY" ohm
- Unplug connector from the fan motor.
- Connect ohmmeter to driver connector pin 2 and ground.
Display: "INFINITY" ohm