AC - signal unclear: Diagnosis/troubleshooting
NOTE:
After troubleshooting, a system test must be carried out!
DIAGNOSIS/TROUBLESHOOTING (FAULT CODE 30, AS OF MY 2002)
| Work instruction | Display OK | If not OK | ||
|---|---|---|---|---|
| 1 | Visual inspection |
|
Step 2 | Step 12 |
| 2 | Check the power supply for the air conditioning compressor |
|
>11 V Step 3 |
Step 6 |
| 3 | Check line between relay for magnetic coupling and air-conditioning system regulator for open circuit |
|
< 2 Step 4 |
Repair wiring harness -> End |
| 4 | Check line between relay for magnetic coupling and magnetic coupling for open circuit |
|
< 2 Step 5 |
Repair wiring harness -> End |
| 5 | Checking the magnetic coupling |
|
Approx. 3 to 5 (at23°C) | Step 23 |
|
Magnetic coupling switches audibly Step 24 |
|||
| 6 | Check line between relay for magnetic coupling and air-conditioning system regulator for short circuit to ground |
|
Step 7 | Repair wiring harness -> End |
| 7 | Check activation on relay for magnetic coupling |
|
Between 0 V und 12 V Fluctuating approx. 3 times per second |
Activation of DME missing Repair wiring harness, or carry out diagnosis DME -> End |
|
> 11 V | Power supply from DME relay pin 5 interrupted Repair wiring harness -> End |
||
|
> 11V | Step 8 | ||
|
< 2 Step 21 |
Open circuit between relay for magnetic coupling and ground point 8 Repair wiring harness -> End |
||
| 8 | Check power supply of relay for fresh-air blower |
|
> 11 V Step 9 |
Open circuit between VS 65 and pin 4 of pressure switch connector Repair wiring harness -> End |
| 9 | Check pressure switch |
|
< 2 Step 10 |
Step 11 |
| 10 | Check line between pressure switch and relay for magnetic clutch for open circuit |
|
< 2 -> End |
Repair wiring harness -> End |
| 11 | Check refrigerant pressure | Step 20 | Repair system and fill -> End |
|
| 12 | Check activation on relay for fresh-air blower |
|
< 2 | Open circuit between relay for fresh-air blower and ground point 3/1 Repair wiring harness -> End |
|
< 0.3V | Open circuit to B+ between relay for fresh-air blower and ground point 3/1 Repair wiring harness -> End |
||
|
>11 V | Step 14 | ||
|
>11 V Step 13 |
Step 17 | ||
| 13 | Check line between relay for fresh-air blower and load for short circuit to ground |
|
Step 22 | Repair wiring harness -> End |
| 14 | Check the power supply for the load |
|
Fuse OK | Replace fuse Step 16 |
|
> 11V Step 15 |
Repair power supply from current distributor -> End |
||
| 15 | Check line between fuse holder D and relay for fresh-air blower for open circuit |
|
< 2 -> End |
Repair wiring harness -> End |
| 16 | Check line between fuse holder D and relay for fresh-air blower for short circuit to ground |
|
-> End | Repair wiring harness -> End |
| 17 | Check the power supply for activation of relay for fresh-air blower |
|
Fuse OK | Replace fuse Step 19 |
|
>11 V Step 18 |
Repair power supply from current distributor -> End |
||
| 18 | Check line between fuse holder C and relay for fresh-air blower for open circuit |
|
< 2 -> End |
Repair wiring harness -> End |
| 19 | Check line between fuse holder C and relay for fresh-air blower for short circuit to ground |
|
< 0.3V -> End |
Repair wiring harness -> End |
| 20 |
|
-> End | ||
| 21 |
|
-> End | ||
| 22 |
|
-> End | ||
| 23 |
|
-> End | ||
| 24 |
|
-> End | ||