Footwell/defrost valve motor - No reaction to activation, signal unclear: Diagnosis/troubleshooting
DIAGNOSIS/TROUBLESHOOTING (FAULT CODE 28, AS OF MY 2002)
| Work instruction | Display OK | If not OK | ||
|---|---|---|---|---|
| 1 | Read out air-conditioning system fault memory |
Step 2
Step 8
See 'SUPPLY VOLTAGE SENSORS (5 V) - TOO HIGH/TOO LOW/SHORT CIRCUIT TO B+/GROUND SHORT '
Step 10 |
||
| 2 | Visual inspection |
|
Connector OK Step 3 |
Clean connector or plug in correctly or repair flap -> End |
| 3 | Check 5 V - supply line to servo motor for footwell/defrost valve |
|
Approx. 5 V Step 4 |
Step 7 |
| 4 | Check signal lead and servo motor lines for short circuit to B+ |
|
< 0.3V Step 5 |
Repair wiring harness -> End |
| 5 | Check signal lead and servo motor lines for short circuit to ground |
|
Step 6 | Repair wiring harness -> End |
| 6 | Check signal line and servo motor line for interruption |
|
< 5 Step 11 |
Repair wiring harness -> End |
| 7 | Check 5 V supply line for short circuit to B+ |
|
< 0.3V Step 8 |
Repair wiring harness -> End |
| 8 | Check 5 V supply line for short circuit to ground |
|
Step 9 | Repair wiring harness -> End |
| 9 | Check 5 V supply lead for open circuit |
|
< 5 Step 10 |
Repair wiring harness -> End |
| 10 | Check ground line for open circuit |
|
< 5 Step 12 |
Repair wiring harness -> End |
| 11 |
|
-> End | ||
| 12 |
|
-> End | ||