8009 CDR23: Diagnosis/troubleshooting

WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2004 Porsche Boxster, 2003 Porsche Boxster, 2002 Porsche Boxster, 2001 Porsche Boxster, and 2000 Porsche Boxster. However, it is still accessible from the selected car via links, so may be relevant.
DIAGNOSIS/TROUBLESHOOTING - 8009 CDR23

Work instruction Display OK If not OK
1 Read out CDR23 fault memory
  • Connect the Porsche System Tester II 9588 to the diagnostic socket; switch on the ignition and the Porsche System Tester II 9588
  • Select 986 as the vehicle type and start the automatic control module search
  • In the Control units menu, select CDR23
  • Click the "> >" key in the Fault memory menu
  • Read out fault memory
  • Erase fault memory
  • Remove ignition key and switch on ignition again
  • Read out fault memory
  • Extract ambient data, press the ">>" key
The fault is remedied
-> End
Fault code is still displayed
Step 2
2 MOST component check runs automatically
  • In the Control units menu, select CDR23
  • Click MOST components check in the function selection and start it with the ">>" key
  • Follow the instructions of the tester
The following text is displayed: Test successfully completed. No faults found.
-> End
Under Faulty device, the tester displays the relevant MOST control module from which a corresponding signal is not recognised
Step 3
3 Open circuit in MOST, optical
  • Replace the optical waveguide for the MOST control module with the optical wavelength test line 9712
  • Select MOST components check and start it again with the ">>" key
The following text is displayed: Test successfully completed. No faults found
Step 4
Step 5
4 Replace the optical waveguide -> End
5 Connect the optical waveguide test line 9712 with the following MOST control module The following text is displayed: Test successfully completed. No faults found Step 6 Step 6