Battery - handling notes
NOTE:
- Battery terminals should not be greased.
- The battery terminal clamps should only be attached without force to prevent damage to the battery housing.
- The tightening torque for the battery clamps is 5 Nm (4 ftlb.).
- If the battery is to be reconnected, proceed according to WORK INSTRUCTIONS AFTER DISCONNECTING THE BATTERY .
- To guarantee that the battery does not leak it is necessary that the original plug accompanying the battery is screwed into the battery openings.
- In the case of loss or damage, only original plugs of the same design should be used.
- The plugs must be fitted with an o-ring seal.
Warning notes and safety regulations for hydrocyanic acid batteries
- -1-
in Fig 1
. Fire, sparks, naked flames and smoking are forbidden:
- Avoid sparking when using cables and electrical devices
- Avoid short circuits.
- In batteries with central venting, there is an increased detonating gas concentration. The venting hose should not be bent or blocked by dirt.
- -2- in Fig 1 . Wear eye protection
- -3- in Fig 1 . Keep children away from acids and batteries.
- -4-
in Fig 1
. Danger of causticization:
- Battery acid is highly caustic, therefore wear protective gloves.
- Do not tip battery, acid can emerge from the venting opening.
NOTE: First aid: Rinse acid splashes to the eyes immediately with clear water for a few minutes. Consult a doctor immediately. Neutralise acid splashes to the skin or clothing immediately with soap suds and rinse again with plenty of water. If acid has been drunk unintentionally, consult a doctor immediately. - -5- in Fig 1 . Observe information on the battery, in the Technical Manual and in the Driver's Manual.
- -6-
in Fig 1
. Danger of explosion:
- A highly explosive detonating gas mixture occurs when charging batteries.
- -7-
in Fig 1
. Disposal:
- Hand in old batteries at a collection point.
- -8- in Fig 1 . Never dispose of old batteries in the domestic rubbish!