Installing fusible element in the current distributor
NOTE:
- The following spare parts must be replaced.
Hexagon nut M 8, 1 piece
Repair kit - replacement fusible element
- Insert new fusible element -1- , using new washers -2- and new hexagon nuts -3- M 5. Tightening torque: 4.0 Nm (3.0 ftlb.)
- Position and engage the blue after-sales service cover -A- .
- Close the current distributor cover until it engages -arrow- .
- Affix the blue service label.
- See REMOVING AND INSTALLING CURRENT DISTRIBUTOR .