Diagnosis/troubleshooting PSM 5.7
DIAGNOSIS/TROUBLESHOOTING PSM 5.7 (FAULT CODE 4276)
| Work instruction | Display OK | If not OK | ||
|---|---|---|---|---|
| 1 | Check supply voltage of the valve relay |
|
>11 V Step 2 |
Check following components:
->End |
| 2 | Replace hydraulic unit | ->End | ||