Fault code 49: Diagnosis/troubleshooting
DIAGNOSIS/TROUBLESHOOTING (FAULT CODE 49)
| Work instruction | Display OK | If not OK | ||
|---|---|---|---|---|
| 1 | Check wire from data link connector to alarm system control module for short circuit to ground. |
|
Step 2 | Repair wiring harness. ->End |
| 2 | Check wire from data link connector to alarm system control module for short circuit to B+. |
|
0 V Step 3 |
Repair wiring harness. ->End |
| 3 | Check wire from data link connector to alarm system control module for open circuit. |
|
< 5 Step 4 |
Repair wiring harness. ->End |
| 4 |
|
->End | ||