Fault code 5: Notes

5 V supply for axle position sensors (angle sensors for HBA)

This fault is stored in the following cases:

  1. Short circuit to voltage/ground in the supply leads between the control module  and angle sensors for HBA  .
  2. Angle sensor for HBA  is faulty.
  3. The control module is faulty.
    NOTE: The 5V supply voltage for the sensors is ensured via terminal 14 on the HBA control module. A fault in this supply lead affects both angle sensors.