Actual values
It is possible to read out the unlock counter under the Actual values menu item.
UNLOCK COUNTER - ACTUAL VALUES MENU
| Menu item |
Function |
|
|
Under this menu item, it is possible to check the electrical and optical MOST during troubleshooting.
- Connect and start the Porsche System Tester II 9588 and switch on the ignition.
- Select 911 (996) in the Vehicle type menu and confirm with the "FORWORD" key.
- Select PCM in the Control modules menu and confirm with the "FORWORD" key.
- Select PCM2 GW in the PCM2 function selection and confirm with the "FORWORD" key.
- Select Actual values in the PCM2 GW function selection and confirm with the "FORWORD" key.
- Select Unlock counter
in the PCM2 GW actual values function selection and confirm with the "FORWORD" key.
- Read out values from the display field.
|