MOST System check (ignition on)
This check must only be carried out when the engine is not running.
MOST SYSTEM CHECK (IGNITION ON)
| Menu item |
Function |
- MOST System check (ignition on.)
|
Using this menu item, a MOST system check can be carried out with the ignition on. The following checks are carried out automatically and their results are displayed.
- Gateway start-up condition is read out.
- MOST installed components list (required and actual installed components list) is analysed.
- Start the ring break diagnosis.
- The results are displayed by the Porsche System Tester II 9588.
- Connect and start the Porsche System Tester II 9588 and switch on the ignition.
- Select Cayenne in the Vehicle type menu and confirm with the "FORWORD" key.
- Select PCM2 in the Control modules menu and confirm with the "FORWORD" key.
- Select MOST components check in the PCM2 function selection and confirm with the "FORWORD" key.
- Select MOST system check (ignition on)
in the Cayenne PCM2 MOST components check function selection and confirm with the "FORWORD" key.
|