8007 Pcm2 MMI: Diagnosis/troubleshooting
TROUBLESHOOTING (8007 PCM2 MMI)
| Work instruction |
Display OK |
If not OK |
| 1 |
Read out PCM2 fault memory. |
- Connect the Porsche System Tester II 9588 to the diagnostic socket, start it and switch on the ignition.
- Select 911 (996) in the Vehicle type menu and confirm with the "FORWORD" key.
- Select PCM in the Control modules menu and confirm with the "FORWORD" key.
- Select PCM2 MMI in the PCM2 function selection and confirm with the "FORWORD" key.
- Select Fault memory in the 911 (996) PCM2 MMI function selection and confirm with the "FORWORD" key.
- Read out fault memory.
- Clear fault memory.
- Remove ignition key and switch on ignition again.
- Read out fault memory.
- Extract ambient data, press the "FORWORD" key.
|
The fault is remedied -> End |
Fault code is still displayed Step 2 |
| 2 |
Read out extended fault memory. |
- Select Extended fault memory in the 911 (996) PCM2 MMI function selection and confirm with the "FORWORD" key.
|
|
A short circuit to ground is displayed Step 3 A short circuit to B+ is displayed Step 5 |
| 3 |
Check diagnosis distribution line for short circuit to ground. |
- Switch off the ignition.
- Disconnect plug connector on PCM2.
- Disconnect plug connector on external Harman/BOSE amplifier (if installed).
- Disconnect plug connector on CD changer (if installed).
- Disconnect plug connector on telephone/telematics (if installed).
- Measure the resistance between the wake-up/diagnosis distribution line and ground.
|
Step 4 |
If the measured value is not reached, correct short circuit to ground in diagnosis distribution line. Step ? |
| 4 |
Determine faulty MOST control module. |
Reconnect all disconnected plug connectors on existing MOST control modules and check the resistance again.
- Reconnect plug connector on telephone/telematics (if installed) and read out measuring device.
- Reconnect plug connector on CD changer and read out measuring device.
- Reconnect plug connector on external Harman/BOSE amplifier (if installed) and read out measuring device.
- Remove navigation module from PCM2 (if installed), then reconnect plug on the PCM2 and read out measuring device.
- Re-insert navigation module into the PCM2 and read out measuring device.
|
Step ? |
If a message appears on the measuring device display when you connect a MOST component, this MOST control module must be replaced. Step 6 |
| 5 |
Check diagnosis distribution line for short circuit to B+ |
- Switch off the ignition.
- Disconnect plug connector on PCM2.
- Disconnect plug connector on external Harman/BOSE amplifier (if installed).
- Disconnect plug connector on CD changer (if installed).
- Disconnect plug connector on telephone/telematics (if installed).
- Switch on ignition.
- Measure the voltage between the wake-up/diagnosis distribution line and ground.
|
< 0.5 V |
> 0.5 V Check wake-up/diagnosis lead for short circuit to B+ and repair if necessary. |
| 6 |
Replace MOST control module. |
- Erase fault memory and then read it out again.
|
-> End |
|