8007 CDR23: Diagnosis/troubleshooting
DIAGNOSIS/TROUBLESHOOTING (8007 CDR23)
| Work instruction | Display OK | If not OK | ||
|---|---|---|---|---|
| 1 | Read out CDR23 fault memory |
|
The fault is remedied -> End |
Fault code is still displayed Step 2 |
| 2 | Check MOST components |
|
|
An optical fault is displayed 3 An electrical fault is displayed 4 |
| 3 | Optical fault | Replace the relevant optical waveguide between the listed faulty components with the optical waveguide test line 9712 that is provided as a special tool. Check MOST components again. | Replace the faulty optical waveguide with the relevant spare part -> END |
Replace the relevant recipient MOST control module STEP 2 |
| 4 | Check diagnosis ring line for open circuit | Check diagnosis ring line between the listed faulty components for an open circuit
|
< 0.5 STEP 5 |
Remove open circuit in diagnosis ring line -> END |
| 5 | Check diagnosis ring line for short circuit to ground | Check diagnosis ring line between the listed faulty components for short circuit to ground
|
STEP 6 | Remove short circuit to ground in diagnosis ring line -> END |
| 6 | Check diagnosis ring line for short circuit to B+ | Check diagnosis ring line between the listed faulty components for short circuit to B+
|
0 V STEP 7 |
Remove short circuit to B+ in diagnosis ring line -> END |
| 7 | Replace PCM2 | -> End | ||