8004 PCM2 - gateway: Diagnosis/troubleshooting
TROUBLESHOOTING (8004 PCM2 - GATEWAY)
| Work instruction | Display OK | If not OK | ||
|---|---|---|---|---|
| 1 | Read out PCM2 fault memory. |
|
-> End | Fault code is displayed. Step 2 |
| 2 | Check CAN comfort leads, CAN (high) and CAN (low) for short circuit. |
|
Step 3. | Repair short circuit in wiring harness between high and low. -> End. |
| 3 | Check CAN comfort (high) for short circuit to ground. |
|
Step 4. | Repair short circuit between CAN comfort (high) and ground. -> End. |
| 4 | Check CAN comfort (low) for short circuit to ground. |
|
Step 5. | Repair short circuit between CAN comfort (low) and ground. -> End. |
| 5 | Check for short circuit between CAN comfort (high) and battery positive connection. |
|
< 0 V. Step 6. |
Repair short circuit between CAN comfort (high) and voltage supply line. -> End. |
| 6 | Check for short circuit between CAN comfort (low) and battery positive connection. |
|
< 0 V Step 7 |
Repair short circuit between CAN comfort (low) and voltage supply line. -> End. |
| 7 | Determine faulty control module. |
|
The fault is remedied by disconnecting the plug connection of a control module. Step 8. |
Step 9. |
| 8 |
|
-> End. | ||
| 9 | Replace PCM2. | -> End. | ||