Removing fusible element from the current distributor
- Remove cover for current distributor and remove the service label.
- Carefully lever off the cover -A- with a screwdriver -arrow- . This will break the locking tabs and the cover can be removed.
- Remove the broken locking tabs from the current distributor.
- Unscrew the two hexagon nuts M 5 -3- from the blown fusible element -1- and remove with the washers -2-.