Fault code 36: Diagnosis/troubleshooting
FAULT CODE 36 DIAGNOSIS PROCEDURE
| Work instruction | Display OK | If not OK | ||
|---|---|---|---|---|
| 1 | Read out instrument cluster fault memory |
|
The fault is remedied -> End |
Step 2 |
| 2 | Check CAN Comfort high for open circuit |
|
< 5 Step 3 |
Repair wiring harness -> End |
| 3 | Check CAN Comfort low for open circuit |
|
< 5 Step 4 |
Repair wiring harness. -> End |
| 4 |
|
-> End | ||