Fault code 31: Diagnosis/troubleshooting
FAULT CODE 31 DIAGNOSIS PROCEDURE
| Work instruction | Display OK | If not OK | ||
|---|---|---|---|---|
| 1 | Check fuse D6 | Step 2 | Replace fuse | |
| 2 | Check relay for fresh-air blower |
|
Battery voltage Step 3 |
Check line between fuse D 6 and relay socket for open circuit/ short circuit to ground. |
| 3 | Check relay for fresh-air blower |
|
Battery voltage Step 4 |
Relay for heating activation faulty or short circuit to ground or open circuit in the line between heating activation relay and the air-conditioning system regulator |
| 4 | Check blower regulator (end setting) |
|
Fault has been remedied Step 5 |
Step 6 |
| 5 | Check blower regulator (end setting) and line for air-conditioning system regulator |
|
< 5 Step 9 |
Repair wiring harness -> End |
| 6 | Check line to blower motor for short to B+ |
|
0 V Step 5 |
Repair wiring harness -> End |
| 7 | Check line to blower motor for short to ground |
|
Step 6 | Repair wiring harness -> End |
| 8 | Check line to blower motor for open circuit |
|
< 5 Step 10 |
Repair wiring harness -> End |
| 9 |
|
-> End | ||
| 10 |
|
-> End | ||