Fault code 25: Diagnosis/troubleshooting
FAULT CODE 25 DIAGNOSIS PROCEDURE
| Work instruction | Display OK | If not OK | ||
|---|---|---|---|---|
| 1 | Check 5 V supply lead for short to B+ |
|
0 V Step 2 |
Repair wiring hamess -> End |
| 2 | Check 5 V - supply line |
|
approx. 5 V Step 4 |
If more than 5.5 V is indicated: Step 8 If 0 V is indicated: Step 3 |
| 3 | Check 5 V supply line for short to ground |
|
Step 3 | Repair wiring hamess -> End |
| 4 | Check potentiometer in the temperature mixing valve. |
|
4 - 5 k Step 5 |
Replace motor for temperature mixing valve. -> End |
| 5 | Check potentiometer in the footwell defrost flap |
|
4 - 5 k Step 6 |
Replace motor for footwell defrost flap. -> End |
| 6 | Check potentiometer in the central flap. |
|
4 - 5 k Step 7 |
Repace motor for temperature mixing valve. -> End |
| 7 | Check potentiometer in der outside air / recirculation valve |
|
4 - 5 k Step 8 |
Replace motor for temperature mixing valve. -> End |
| 8 |
|
->End | ||