Fault code 24: Diagnosis/troubleshooting
FAULT CODE 24 DIAGNOSIS PROCEDURE
| Work instruction | Display OK | If not OK | ||
|---|---|---|---|---|
| 1 | Check battery. | Step 2 | Charge or replace battery -> End |
|
| 2 | Check the generator. |
|
Step 3 | Replace generator -> End |
| 3 | Check contact resistance of wire connections. |
|
Battery voltage -> End |
Check wiring harness for fuse E7. Check wiring harness for ground point 4. -> End |