Home >> Porsche >> 2000 >> Boxster Base, Standard >> Repair and Diagnosis >> Engine Mechanical >> Fuel System >> Fuel System, Electronic Injection >> Removing and installing oxygen sensors in front of catalytic converter - as of MY 2003 >> Removing oxygen sensors in front of catalytic converter - RoW

Removing oxygen sensors in front of catalytic converter - RoW

  1. Remove respective rear wheel. To do this, use the socket wrench insert P 300 to avoid damaging the wheel.
  2. Remove oxygen sensor cable and oxygen sensor plug from the holder on the axle support -arrow-.  Refer to Fig 1 .
    Fig 1: Removing Oxygen Sensor Cable & Oxygen Sensor Plug From Holder On Axle Support (RoW)
    G03138981Courtesy of PORSCHE OF NORTH AMERICA, INC.
  3. Unlock and disconnect oxygen sensor plug by pulling the plug lock out sideways. Use a small screwdriver to open the plug lock at the side. Refer to Fig 2 .
    Fig 2: Opening Oxygen Sensor Plug Lock (RoW)
    G03138982Courtesy of PORSCHE OF NORTH AMERICA, INC.
  4. Undo oxygen sensor using an open-ended wrench (wrench size 22) and screw it out by hand.