8009 Pcm2 - MMI: Diagnosis/troubleshooting
DIAGNOSIS/TROUBLESHOOTING - 8009 PCM2 - MMI
| Work instruction | Display OK | If not OK | ||
|---|---|---|---|---|
| 1 | MOST component check runs automatically |
|
The following text is displayed: Test successfully completed. No faults found. -> End |
Tester displays an optical fault: Under Faulty device, the tester displays the relevant MOST control module from which a corresponding signal is not recognised Step 2 Tester displays an electrical fault Step 7 |
| 2 | Open circuit in MOST, optical |
|
The following text is displayed: Test successfully completed. No faults found Step 3 |
Step 4 |
| 3 | Replace the optical waveguide | -> End | ||
| 4 | Open circuit in MOST, optical | If an MMI or GW fault is displayed under step 1:
|
||
| - | If only 1 external MOST control module is present and fault memory entry under step 1 is not MMI or GW: | If only 1 external MOST control module is present and fault memory entry under step 1 is not MMI or GW: fault memory entry 8009 = MMI or GW Step 6 |
If only 1 external MOST control module is present and fault memory entry under step 1 is not MMI or GW: fault memory entry 8009 is not MMI or GW Step 5 |
- |
| - | - | Otherwise
|
Otherwise: The following text is displayed: Test successfully completed. No faults found. Step 6 |
Otherwise: Step 7 |
| - | - | After installation Optical waveguide test line 9712 :
|
-> End | |
| 5 | Replace the control module displayed under step 1. | -> End | ||
| 6 | Replace the control module before the one displayed under step 1. | -> End | ||
| 7 | Check the power supply of the displayed control module. | Step 6 | Repair -> End |
|
| 8 | Check wiring of the ring break diagnosis line. | Step 6 | Repair -> End |
|
| 9 | Replace displayed control module | -> End | ||