8004 PCM2 - gateway: Diagnosis/troubleshooting
DIAGNOSIS/TROUBLESHOOTING - 8004 PCM2 - GATEWAY
| Work instruction | Display OK | If not OK | ||
|---|---|---|---|---|
| 1 | Read out PCM2 fault memory |
|
-> End | Fault code is displayed Step 2 |
| 2 | Check CAN bus leads, CAN-high and CAN-low for short circuit |
|
Step 3 | Repair short circuit in wiring harness between high and low -> End |
| 3 | Check CAN comfort (high) for short circuit to ground |
|
Step 4 | Repair short circuit between CAN comfort (high) and ground -> End |
| 4 | Check CAN comfort (low) for short circuit to ground |
|
Step 5 | Repair short circuit between CAN comfort (low) and ground -> End |
| 5 | Check short circuit between CAN comfort (high) and battery positive connection |
|
< 0 V Step 6 |
Repair short circuit between CAN comfort (high) and voltage supply line -> End |
| 6 | Check for short circuit between CAN comfort (low) and battery positive connection |
|
< 0 V Step 7 |
Repair short circuit between CAN comfort (low) and voltage supply line -> End |
| 7 | Determine faulty control unit |
|
The fault is remedied by disconnecting the plug connection of a control module Step 8 |
Step 9 |
| 8 |
|
-> End | - | |
| 9 | Replace PCM2 | -> End | ||