Fault code 2: Elimination:
- Switch off ignition
- Pull plug off the control module
- Pull plug off the servomotor for HBA
- Check for open circuit in the supply leads to the servomotor for HBA, right,
terminals 5, 6, 7, 8
Ohmmeter display < 5 Ohm
- Check for short to B+ in the supply leads to the servomotor for HBA
Ohmmeter connected to terminals 5, 6, 7, and 8; measure resistance to ground
Ohmmeter display "INFINITY" Ohm
- Check for short circuits between the leads.
- If no fault is detected in the wires, replace the servomotor for HBA.