Check Electric Change-Over Valve
- Remove two-pole connector of electric change-over valve.
- Connect voltmeter to pin 1 (positive) and pin 2 (negative).
- Trigger AIR pump with Porsche System Tester 2.
Display: battery voltage
- Remove vacuum hoses of electric change-over valve with the engine running. Check whether vacuum is present.