Check Oxygen Sensor Heating
- Remove oxygen sensor connector 2 ahead of TWC.
- Connect ohmmeter to pins 1 and 2 of the oxygen sensor connector towards to oxygen sensor.
Display: 1.0-2.6 ohms at 25° C
- Connect ohmmeter to pin 1 of the oxygen sensor connector towards the oxygen sensor and the oxygen sensor housing.
Display: infinity ohms
- Connect ohmmeter to pin 2 of the oxygen sensor connector towards the oxygen sensor and the oxygen sensor housing.
Display: infinity ohms