Check wiring harness
- Remove oxygen sensor connector 1 ahead of TWC.
- Switch on the ignition.
- Connect voltmeter at sleeve to pins 3 and 4 of oxygen sensor connector 1 ahead of TWC.
Display: approx. 450 mV
If the value is not reached, remove DME control module connector and check wiring for short to B+.
If no short to B+ can be detected, replace DME control module.